Added hint regarding retained flag for nonpersistent values to documentation
This commit is contained in:
parent
b106504730
commit
a4316c89b4
@ -67,7 +67,7 @@ cmd topics are used to set values. Status topics are updated from values set in
|
||||
| [serial]/status/limit_absolute | R | Current applied production limit of the inverter | Watt (W) |
|
||||
| [serial]/cmd/limit_persistent_relative | W | Set the inverter limit as a percentage of total production capability. The value will survive the night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. | % |
|
||||
| [serial]/cmd/limit_persistent_absolute | W | Set the inverter limit as a absolute value. The value will survive the night without power. The updated value will set immediatly within the inverter but show up in the web GUI and limit_relative topic after around 4 minutes. If you are using a already known inverter (known Hardware ID), the updated value will show up within a few seconds. | Watt (W) |
|
||||
| [serial]/cmd/limit_nonpersistent_relative | W | Set the inverter limit as a percentage of total production capability. The value will reset to the last persistent value at night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. | % |
|
||||
| [serial]/cmd/limit_nonpersistent_absolute | W | Set the inverter limit as a absolute value. The value will reset to the last persistent value at night without power. The updated value will set immediatly within the inverter but show up in the web GUI and limit_relative topic after around 4 minutes. If you are using a already known inverter (known Hardware ID), the updated value will show up within a few seconds. | Watt (W) |
|
||||
| [serial]/cmd/limit_nonpersistent_relative | W | Set the inverter limit as a percentage of total production capability. The value will reset to the last persistent value at night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. The value must be published non-retained, otherwise it will be ignored! | % |
|
||||
| [serial]/cmd/limit_nonpersistent_absolute | W | Set the inverter limit as a absolute value. The value will reset to the last persistent value at night without power. The updated value will set immediatly within the inverter but show up in the web GUI and limit_relative topic after around 4 minutes. If you are using a already known inverter (known Hardware ID), the updated value will show up within a few seconds. The value must be published non-retained, otherwise it will be ignored! | Watt (W) |
|
||||
| [serial]/cmd/power | W | Turn the inverter on (1) or off (0) | 0 or 1 |
|
||||
| [serial]/cmd/restart | W | Restarts the inverters (also resets YieldDay) | 1 |
|
||||
|
||||