DPL: replace _plState enum with a simple boolean switch
This commit is contained in:
parent
b2d58af5e8
commit
9bab740c43
@ -53,15 +53,8 @@ public:
|
||||
void calcNextInverterRestart();
|
||||
|
||||
private:
|
||||
enum class plStates : unsigned {
|
||||
INIT, // looping for the first time after system startup
|
||||
ACTIVE, // normal operation, sending power limit updates to inverter
|
||||
SHUTDOWN, // power limiter shuts down inverter
|
||||
OFF // inverter was shut down, power limiter is NOT active
|
||||
};
|
||||
|
||||
int32_t _lastRequestedPowerLimit = 0;
|
||||
plStates _plState = plStates::INIT;
|
||||
bool _shutdownInProgress;
|
||||
Status _lastStatus = Status::Initializing;
|
||||
uint32_t _lastStatusPrinted = 0;
|
||||
uint8_t _mode = PL_MODE_ENABLE_NORMAL_OP;
|
||||
|
||||
@ -69,16 +69,14 @@ void PowerLimiterClass::shutdown(PowerLimiterClass::Status status)
|
||||
{
|
||||
announceStatus(status);
|
||||
|
||||
if (_plState == plStates::OFF) { return; }
|
||||
|
||||
_plState = plStates::SHUTDOWN;
|
||||
|
||||
if (_inverter == nullptr || !_inverter->isProducing() || !_inverter->isReachable()) {
|
||||
_inverter = nullptr;
|
||||
_plState = plStates::OFF;
|
||||
_shutdownInProgress = false;
|
||||
return;
|
||||
}
|
||||
|
||||
_shutdownInProgress = true;
|
||||
|
||||
auto lastLimitCommandState = _inverter->SystemConfigPara()->getLastLimitCommandSuccess();
|
||||
if (CMD_PENDING == lastLimitCommandState) { return; }
|
||||
|
||||
@ -93,7 +91,7 @@ void PowerLimiterClass::loop()
|
||||
{
|
||||
CONFIG_T& config = Configuration.get();
|
||||
|
||||
if (plStates::SHUTDOWN == _plState) {
|
||||
if (_shutdownInProgress) {
|
||||
// we transition from SHUTDOWN to OFF when we know the inverter was
|
||||
// shut down. until then, we retry shutting it down. in this case we
|
||||
// preserve the original status that lead to the decision to shut down.
|
||||
@ -126,9 +124,6 @@ void PowerLimiterClass::loop()
|
||||
// update our pointer as the configuration might have changed
|
||||
_inverter = currentInverter;
|
||||
|
||||
// controlling an inverter means the DPL will shut it down eventually
|
||||
_plState = plStates::ACTIVE;
|
||||
|
||||
// data polling is disabled or the inverter is deemed offline
|
||||
if (!_inverter->isReachable()) {
|
||||
return announceStatus(Status::InverterOffline);
|
||||
|
||||
Loading…
Reference in New Issue