fix an issue if inverter is behind power meter
This commit is contained in:
parent
82699b1c88
commit
8c9afbcdc0
@ -149,14 +149,6 @@ int32_t PowerLimiterClass::calcPowerLimit(std::shared_ptr<InverterAbstract> inve
|
|||||||
return config.PowerLimiter_LowerPowerLimit;
|
return config.PowerLimiter_LowerPowerLimit;
|
||||||
}
|
}
|
||||||
|
|
||||||
// check if grid power consumption is within the limits of the target consumption + hysteresis
|
|
||||||
if (newPowerLimit >= (config.PowerLimiter_TargetPowerConsumption - config.PowerLimiter_TargetPowerConsumptionHysteresis) &&
|
|
||||||
newPowerLimit <= (config.PowerLimiter_TargetPowerConsumption + config.PowerLimiter_TargetPowerConsumptionHysteresis)) {
|
|
||||||
// The values have not changed much. We just use the old setting
|
|
||||||
MessageOutput.println("[PowerLimiterClass::loop] reusing old limit");
|
|
||||||
return _lastRequestedPowerLimit;
|
|
||||||
}
|
|
||||||
|
|
||||||
if (config.PowerLimiter_IsInverterBehindPowerMeter) {
|
if (config.PowerLimiter_IsInverterBehindPowerMeter) {
|
||||||
// If the inverter the behind the power meter (part of measurement),
|
// If the inverter the behind the power meter (part of measurement),
|
||||||
// the produced power of this inverter has also to be taken into account.
|
// the produced power of this inverter has also to be taken into account.
|
||||||
@ -165,6 +157,16 @@ int32_t PowerLimiterClass::calcPowerLimit(std::shared_ptr<InverterAbstract> inve
|
|||||||
float acPower = inverter->Statistics()->getChannelFieldValue(TYPE_AC, (ChannelNum_t) config.PowerLimiter_InverterChannelId, FLD_PAC);
|
float acPower = inverter->Statistics()->getChannelFieldValue(TYPE_AC, (ChannelNum_t) config.PowerLimiter_InverterChannelId, FLD_PAC);
|
||||||
newPowerLimit += static_cast<int>(acPower);
|
newPowerLimit += static_cast<int>(acPower);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
// check if grid power consumption is within the limits of the target consumption + hysteresis
|
||||||
|
if (newPowerLimit >= (config.PowerLimiter_TargetPowerConsumption - config.PowerLimiter_TargetPowerConsumptionHysteresis) &&
|
||||||
|
newPowerLimit <= (config.PowerLimiter_TargetPowerConsumption + config.PowerLimiter_TargetPowerConsumptionHysteresis)) {
|
||||||
|
// The values have not changed much. We just use the old setting
|
||||||
|
MessageOutput.println("[PowerLimiterClass::loop] reusing old limit");
|
||||||
|
return _lastRequestedPowerLimit;
|
||||||
|
}
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
float efficency = inverter->Statistics()->getChannelFieldValue(TYPE_AC, (ChannelNum_t) config.PowerLimiter_InverterChannelId, FLD_EFF);
|
float efficency = inverter->Statistics()->getChannelFieldValue(TYPE_AC, (ChannelNum_t) config.PowerLimiter_InverterChannelId, FLD_EFF);
|
||||||
int32_t victronChargePower = this->getDirectSolarPower();
|
int32_t victronChargePower = this->getDirectSolarPower();
|
||||||
|
|||||||