Merge pull request #244 from dersch81/patch-1

Update MQTT_Topics.md
This commit is contained in:
tbnobody 2022-10-18 21:41:23 +02:00 committed by GitHub
commit 7571db75ce
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23

View File

@ -39,7 +39,7 @@ serial will be replaced with the serial number of the inverter.
| [serial]/0/temperature | R | Temperature of inverter in degree celsius | Degree Celsius (°C) | | [serial]/0/temperature | R | Temperature of inverter in degree celsius | Degree Celsius (°C) |
| [serial]/0/voltage | R | AC voltage in volt | Volt (V) | | [serial]/0/voltage | R | AC voltage in volt | Volt (V) |
| [serial]/0/yieldday | R | Energy converted to AC per day in watt hours | Watt hours (Wh) | | [serial]/0/yieldday | R | Energy converted to AC per day in watt hours | Watt hours (Wh) |
| [serial]/0/yieldtotal | R | Energy converted to AC since reset watt hours | Watt hours (Wh) | | [serial]/0/yieldtotal | R | Energy converted to AC since reset watt hours | Watt hours (kWh) |
### DC input channel topics ### DC input channel topics
@ -52,7 +52,7 @@ serial will be replaced with the serial number of the inverter.
| [serial]/[1-4]/power | R | DC power of specific input in watt | Watt (W) | | [serial]/[1-4]/power | R | DC power of specific input in watt | Watt (W) |
| [serial]/[1-4]/voltage | R | DC voltage of specific input in volt | Volt (V) | | [serial]/[1-4]/voltage | R | DC voltage of specific input in volt | Volt (V) |
| [serial]/[1-4]/yieldday | R | Energy converted to AC per day on specific input | Watt hours (Wh) | | [serial]/[1-4]/yieldday | R | Energy converted to AC per day on specific input | Watt hours (Wh) |
| [serial]/[1-4]/yieldtotal | R | Energy converted to AC since reset on specific input | Watt hours (Wh) | | [serial]/[1-4]/yieldtotal | R | Energy converted to AC since reset on specific input | Watt hours (kWh) |
### Inverter limit specific topics ### Inverter limit specific topics
@ -69,4 +69,4 @@ cmd topics are used to set values. Status topics are updated from values set in
| [serial]/cmd/limit_nonpersistent_relative | W | Set the inverter limit as a percentage of total production capability. The value will reset to the last persistent value at night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. | % | | [serial]/cmd/limit_nonpersistent_relative | W | Set the inverter limit as a percentage of total production capability. The value will reset to the last persistent value at night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. | % |
| [serial]/cmd/limit_nonpersistent_absolute | W | Set the inverter limit as a absolute value. The value will reset to the last persistent value at night without power. The updated value will show up in the web GUI and limit_relative topic after around 4 minutes. | Watt (W) | | [serial]/cmd/limit_nonpersistent_absolute | W | Set the inverter limit as a absolute value. The value will reset to the last persistent value at night without power. The updated value will show up in the web GUI and limit_relative topic after around 4 minutes. | Watt (W) |
| [serial]/cmd/power | W | Turn the inverter on (1) or off (0) | 0 or 1 | | [serial]/cmd/power | W | Turn the inverter on (1) or off (0) | 0 or 1 |
| [serial]/cmd/restart | W | Restarts the inverters (also resets YieldDay) | 1 | | [serial]/cmd/restart | W | Restarts the inverters (also resets YieldDay) | 1 |