fixing a bug from merging and remove a leftover debug message
This commit is contained in:
parent
be7a43fbfb
commit
690025e5fd
@ -24,7 +24,7 @@ void PowerLimiterClass::loop()
|
||||
CONFIG_T& config = Configuration.get();
|
||||
|
||||
// Run inital checks to make sure we have met the basic conditions
|
||||
if ( !config.PowerMeter_Enabled
|
||||
if (!config.PowerMeter_Enabled
|
||||
|| !Hoymiles.getRadio()->isIdle()
|
||||
|| (millis() - _lastLoop) < (config.PowerLimiter_Interval * 1000)) {
|
||||
return;
|
||||
@ -95,8 +95,6 @@ void PowerLimiterClass::loop()
|
||||
// Calculate and set Power Limit
|
||||
int32_t newPowerLimit = calcPowerLimit(inverter, !_batteryDischargeEnabled);
|
||||
setNewPowerLimit(inverter, newPowerLimit);
|
||||
// Debug, TODO: Remove
|
||||
MessageOutput.printf("****************************** Powerlimit: %i\r\n", newPowerLimit);
|
||||
}
|
||||
|
||||
plStates PowerLimiterClass::getPowerLimiterState() {
|
||||
@ -175,16 +173,9 @@ int32_t PowerLimiterClass::calcPowerLimit(std::shared_ptr<InverterAbstract> inve
|
||||
MessageOutput.printf("[PowerLimiterClass::loop] victronChargePower: %d, efficiency: %.2f, consumeSolarPowerOnly: %s, powerConsumption: %d \r\n",
|
||||
victronChargePower, efficency, consumeSolarPowerOnly ? "true" : "false", newPowerLimit);
|
||||
|
||||
// Safety check: Are the power meter values not too old?
|
||||
// Are the reported inverter data not too old?
|
||||
if (millis() - PowerMeter.getLastPowerMeterUpdate() < (30 * 1000)
|
||||
&& millis() - inverter->Statistics()->getLastUpdate() < (15 * 1000)) {
|
||||
if (config.PowerLimiter_IsInverterBehindPowerMeter) {
|
||||
// If the inverter the behind the power meter (part of measurement),
|
||||
// the produced power of this inverter has also to be taken into account.
|
||||
float acPower = inverter->Statistics()->getChannelFieldValue(TYPE_AC, (ChannelNum_t) config.PowerLimiter_InverterChannelId, FLD_PAC);
|
||||
newPowerLimit += static_cast<int>(acPower);
|
||||
}
|
||||
// We're not trying to hit 0 exactly but take an offset into account
|
||||
// This means we never fully compensate the used power with the inverter
|
||||
newPowerLimit -= config.PowerLimiter_TargetPowerConsumption;
|
||||
|
||||
int32_t upperPowerLimit = config.PowerLimiter_UpperPowerLimit;
|
||||
if (consumeSolarPowerOnly && (upperPowerLimit > adjustedVictronChargePower)) {
|
||||
|
||||
Loading…