fix setting consumeSolarPowerOnly
This commit is contained in:
parent
67a5217482
commit
6709338dbd
@ -40,7 +40,7 @@ void PowerLimiterClass::init()
|
|||||||
MqttSettings.subscribe(config.PowerLimiter_MqttTopicPowerMeter3, 0, std::bind(&PowerLimiterClass::onMqttMessage, this, _1, _2, _3, _4, _5, _6));
|
MqttSettings.subscribe(config.PowerLimiter_MqttTopicPowerMeter3, 0, std::bind(&PowerLimiterClass::onMqttMessage, this, _1, _2, _3, _4, _5, _6));
|
||||||
}
|
}
|
||||||
|
|
||||||
_consumeSolarPowerOnly = false;
|
_consumeSolarPowerOnly = true;
|
||||||
}
|
}
|
||||||
|
|
||||||
void PowerLimiterClass::onMqttMessage(const espMqttClientTypes::MessageProperties& properties, const char* topic, const uint8_t* payload, size_t len, size_t index, size_t total)
|
void PowerLimiterClass::onMqttMessage(const espMqttClientTypes::MessageProperties& properties, const char* topic, const uint8_t* payload, size_t len, size_t index, size_t total)
|
||||||
@ -92,10 +92,10 @@ void PowerLimiterClass::loop()
|
|||||||
|
|
||||||
uint16_t victronChargePower = this->getDirectSolarPower();
|
uint16_t victronChargePower = this->getDirectSolarPower();
|
||||||
|
|
||||||
MessageOutput.printf("[PowerLimiterClass::loop] victronChargePower: %d\r\n", victronChargePower);
|
MessageOutput.printf("[PowerLimiterClass::loop] victronChargePower: %d, consumeSolarPowerOnly: %s \r\n", victronChargePower, _consumeSolarPowerOnly ? "true" : "false");
|
||||||
|
|
||||||
if (millis() - _lastPowerMeterUpdate < (30 * 1000)) {
|
if (millis() - _lastPowerMeterUpdate < (30 * 1000)) {
|
||||||
MessageOutput.printf("[PowerLimiterClass::loop] dcVoltage: %.2f config.PowerLimiter_VoltageStartThreshold: %.2f config.PowerLimiter_VoltageStopThreshold: %.2f inverter->isProducing(): %d\r\n",
|
MessageOutput.printf("[PowerLimiterClass::loop] dcVoltage: %.2f Voltage Start Threshold: %.2f Voltage Stop Threshold: %.2f inverter->isProducing(): %d\r\n",
|
||||||
dcVoltage, config.PowerLimiter_VoltageStartThreshold, config.PowerLimiter_VoltageStopThreshold, inverter->isProducing());
|
dcVoltage, config.PowerLimiter_VoltageStartThreshold, config.PowerLimiter_VoltageStopThreshold, inverter->isProducing());
|
||||||
}
|
}
|
||||||
|
|
||||||
@ -109,7 +109,7 @@ void PowerLimiterClass::loop()
|
|||||||
|| !canUseDirectSolarPower()) {
|
|| !canUseDirectSolarPower()) {
|
||||||
// The battery is full enough again, use the full battery power from now on.
|
// The battery is full enough again, use the full battery power from now on.
|
||||||
_consumeSolarPowerOnly = false;
|
_consumeSolarPowerOnly = false;
|
||||||
} else if (!_consumeSolarPowerOnly && isStopThresholdReached(inverter) && canUseDirectSolarPower()) {
|
} else if (!_consumeSolarPowerOnly && !isStopThresholdReached(inverter) && canUseDirectSolarPower()) {
|
||||||
// The battery voltage dropped too low
|
// The battery voltage dropped too low
|
||||||
_consumeSolarPowerOnly = true;
|
_consumeSolarPowerOnly = true;
|
||||||
}
|
}
|
||||||
|
|||||||