Split Huawei setValue in private/public implementation. Prevent setting values when internal power control mode is enabled (#521)
This commit is contained in:
parent
d4d42167ec
commit
3dceddfe49
@ -129,6 +129,7 @@ public:
|
||||
|
||||
private:
|
||||
void processReceivedParameters();
|
||||
void _setValue(float in, uint8_t parameterType);
|
||||
|
||||
TaskHandle_t _HuaweiCanCommunicationTaskHdl = NULL;
|
||||
bool _initialized = false;
|
||||
|
||||
@ -297,7 +297,7 @@ void HuaweiCanClass::loop()
|
||||
// Set voltage limit in periodic intervals
|
||||
if ( _nextAutoModePeriodicIntMillis < millis()) {
|
||||
MessageOutput.printf("[HuaweiCanClass::loop] Periodically setting voltage limit: %f \r\n", config.Huawei_Auto_Power_Voltage_Limit);
|
||||
setValue(config.Huawei_Auto_Power_Voltage_Limit, HUAWEI_ONLINE_VOLTAGE);
|
||||
_setValue(config.Huawei_Auto_Power_Voltage_Limit, HUAWEI_ONLINE_VOLTAGE);
|
||||
_nextAutoModePeriodicIntMillis = millis() + 60000;
|
||||
}
|
||||
|
||||
@ -319,7 +319,7 @@ void HuaweiCanClass::loop()
|
||||
|
||||
if (inverter != nullptr) {
|
||||
if(inverter->isProducing()) {
|
||||
setValue(0.0, HUAWEI_ONLINE_CURRENT);
|
||||
_setValue(0.0, HUAWEI_ONLINE_CURRENT);
|
||||
// Don't run auto mode for a second now. Otherwise we may send too much over the CAN bus
|
||||
_autoModeBlockedTillMillis = millis() + 1000;
|
||||
MessageOutput.printf("[HuaweiCanClass::loop] Inverter is active, disable\r\n");
|
||||
@ -349,7 +349,7 @@ void HuaweiCanClass::loop()
|
||||
_autoPowerEnabledCounter--;
|
||||
if (_autoPowerEnabledCounter == 0) {
|
||||
_autoPowerEnabled = false;
|
||||
setValue(0, HUAWEI_ONLINE_CURRENT);
|
||||
_setValue(0, HUAWEI_ONLINE_CURRENT);
|
||||
return;
|
||||
}
|
||||
} else {
|
||||
@ -366,20 +366,27 @@ void HuaweiCanClass::loop()
|
||||
float outputCurrent = efficiency * (newPowerLimit / _rp.output_voltage);
|
||||
MessageOutput.printf("[HuaweiCanClass::loop] Output current %f \r\n", outputCurrent);
|
||||
_autoPowerEnabled = true;
|
||||
setValue(outputCurrent, HUAWEI_ONLINE_CURRENT);
|
||||
_setValue(outputCurrent, HUAWEI_ONLINE_CURRENT);
|
||||
|
||||
// Don't run auto mode some time to allow for output stabilization after issuing a new value
|
||||
_autoModeBlockedTillMillis = millis() + 2 * HUAWEI_DATA_REQUEST_INTERVAL_MS;
|
||||
} else {
|
||||
// requested PL is below minium. Set current to 0
|
||||
_autoPowerEnabled = false;
|
||||
setValue(0.0, HUAWEI_ONLINE_CURRENT);
|
||||
_setValue(0.0, HUAWEI_ONLINE_CURRENT);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
void HuaweiCanClass::setValue(float in, uint8_t parameterType)
|
||||
{
|
||||
if (_mode != HUAWEI_MODE_AUTO_INT) {
|
||||
_setValue(in, parameterType);
|
||||
}
|
||||
}
|
||||
|
||||
void HuaweiCanClass::_setValue(float in, uint8_t parameterType)
|
||||
{
|
||||
|
||||
const CONFIG_T& config = Configuration.get();
|
||||
@ -391,7 +398,7 @@ void HuaweiCanClass::setValue(float in, uint8_t parameterType)
|
||||
uint16_t value;
|
||||
|
||||
if (in < 0) {
|
||||
MessageOutput.printf("[HuaweiCanClass::setValue] Error: Tried to set voltage/current to negative value %f \r\n", in);
|
||||
MessageOutput.printf("[HuaweiCanClass::_setValue] Error: Tried to set voltage/current to negative value %f \r\n", in);
|
||||
}
|
||||
|
||||
// Start PSU if needed
|
||||
@ -435,7 +442,7 @@ void HuaweiCanClass::setMode(uint8_t mode) {
|
||||
|
||||
if (_mode == HUAWEI_MODE_AUTO_INT && mode != HUAWEI_MODE_AUTO_INT) {
|
||||
_autoPowerEnabled = false;
|
||||
setValue(0, HUAWEI_ONLINE_CURRENT);
|
||||
_setValue(0, HUAWEI_ONLINE_CURRENT);
|
||||
}
|
||||
|
||||
if(mode == HUAWEI_MODE_AUTO_EXT || mode == HUAWEI_MODE_AUTO_INT) {
|
||||
|
||||
Loading…