@ -141,12 +141,12 @@ int32_t PowerLimiterClass::calcPowerLimit(std::shared_ptr<InverterAbstract> inve
// Safety check, return on too old power meter values
if (millis() - PowerMeter.getLastPowerMeterUpdate() > (30 * 1000)
&& (millis() - inverter->Statistics()->getLastUpdate()) > (config.Dtu_PollInterval * 3 * 1000)) {
&& (millis() - inverter->Statistics()->getLastUpdate()) > (config.Dtu_PollInterval * 10 * 1000)) {
// If the power meter values are older than 30 seconds,
// and the Inverter Stats are older then 3x the poll interval
// set the limit to config.PowerLimiter_LowerPowerLimit for safety reasons.
MessageOutput.println("[PowerLimiterClass::loop] Power Meter values too old. Using lower limit");
return config.PowerLimiter_LowerPowerLimit;
// and the Inverter Stats are older then 10x the poll interval
// set the limit to 0W for safety reasons.
MessageOutput.println("[PowerLimiterClass::loop] Power Meter/Inverter values too old. Using 0W (i.e. disable inverter)");
return 0;
}
if (config.PowerLimiter_IsInverterBehindPowerMeter) {
@ -157,17 +157,21 @@ int32_t PowerLimiterClass::calcPowerLimit(std::shared_ptr<InverterAbstract> inve
float acPower = inverter->Statistics()->getChannelFieldValue(TYPE_AC, (ChannelNum_t) config.PowerLimiter_InverterChannelId, FLD_PAC);
newPowerLimit += static_cast<int>(acPower);
}
// check if grid power consumption is within the limits of the target consumption + hysteresis
if (newPowerLimit >= (config.PowerLimiter_TargetPowerConsumption - config.PowerLimiter_TargetPowerConsumptionHysteresis) &&
newPowerLimit <= (config.PowerLimiter_TargetPowerConsumption + config.PowerLimiter_TargetPowerConsumptionHysteresis)) {
// The values have not changed much. We just use the old setting
MessageOutput.println("[PowerLimiterClass::loop] reusing old limit");
return _lastRequestedPowerLimit;
// We're not trying to hit 0 exactly but take an offset into account
// This means we never fully compensate the used power with the inverter
newPowerLimit -= config.PowerLimiter_TargetPowerConsumption;
// Check if the new value is within the limits of the hysteresis and
// if we're not limited to Solar Power only (i.e. we can discharge the battery)
// If things did not change much we just use the old setting
if (newPowerLimit >= (-config.PowerLimiter_TargetPowerConsumptionHysteresis) &&
newPowerLimit <= (+config.PowerLimiter_TargetPowerConsumptionHysteresis) &&
!consumeSolarPowerOnly ) {
MessageOutput.println("[PowerLimiterClass::loop] reusing old limit");
return _lastRequestedPowerLimit;
}
float efficency = inverter->Statistics()->getChannelFieldValue(TYPE_AC, (ChannelNum_t) config.PowerLimiter_InverterChannelId, FLD_EFF);
int32_t victronChargePower = this->getDirectSolarPower();
int32_t adjustedVictronChargePower = victronChargePower * (efficency > 0.0 ? (efficency / 100.0) : 1.0); // if inverter is off, use 1.0
@ -175,10 +179,6 @@ int32_t PowerLimiterClass::calcPowerLimit(std::shared_ptr<InverterAbstract> inve
MessageOutput.printf("[PowerLimiterClass::loop] victronChargePower: %d, efficiency: %.2f, consumeSolarPowerOnly: %s, powerConsumption: %d \r\n",
victronChargePower, efficency, consumeSolarPowerOnly ? "true" : "false", newPowerLimit);
// We're not trying to hit 0 exactly but take an offset into account
// This means we never fully compensate the used power with the inverter
newPowerLimit -= config.PowerLimiter_TargetPowerConsumption;
int32_t upperPowerLimit = config.PowerLimiter_UpperPowerLimit;
if (consumeSolarPowerOnly && (upperPowerLimit > adjustedVictronChargePower)) {
// Battery voltage too low, use Victron solar power (corrected by efficiency factor) only