From 304d90062d22b9c89e5057e2f9fa0c6e69b7af81 Mon Sep 17 00:00:00 2001 From: Bernhard Kaszt Date: Sun, 5 Mar 2023 16:30:53 +0100 Subject: [PATCH] Revert broken change in condition that sets _consumeSolarPowerOnly https://github.com/helgeerbe/OpenDTU-OnBattery/commit/6709338dbd5b989f109ff2721228b340b4e93288 --- src/PowerLimiter.cpp | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/src/PowerLimiter.cpp b/src/PowerLimiter.cpp index d0af9276..0b2cac15 100644 --- a/src/PowerLimiter.cpp +++ b/src/PowerLimiter.cpp @@ -110,7 +110,7 @@ void PowerLimiterClass::loop() if ((_consumeSolarPowerOnly && isStartThresholdReached(inverter))) { // The battery is full enough again, use the full battery power from now on. _consumeSolarPowerOnly = false; - } else if (!_consumeSolarPowerOnly && !isStopThresholdReached(inverter) && canUseDirectSolarPower()) { + } else if (!_consumeSolarPowerOnly && isStopThresholdReached(inverter) && canUseDirectSolarPower()) { // The battery voltage dropped too low _consumeSolarPowerOnly = true; }