From 27ed4e3cda81cc26f8c176b7254c9d735a008737 Mon Sep 17 00:00:00 2001 From: Thomas Basler Date: Mon, 31 Oct 2022 10:50:31 +0100 Subject: [PATCH] BREAKING: Change power factor from percent value to value between 0 and 1 If you write these values to a database you have to update them. --- lib/Hoymiles/src/inverters/HM_1CH.h | 2 +- lib/Hoymiles/src/inverters/HM_2CH.h | 2 +- lib/Hoymiles/src/inverters/HM_4CH.h | 2 +- 3 files changed, 3 insertions(+), 3 deletions(-) diff --git a/lib/Hoymiles/src/inverters/HM_1CH.h b/lib/Hoymiles/src/inverters/HM_1CH.h index 8b4667d8..318bfc79 100644 --- a/lib/Hoymiles/src/inverters/HM_1CH.h +++ b/lib/Hoymiles/src/inverters/HM_1CH.h @@ -24,7 +24,7 @@ private: { FLD_PAC, UNIT_W, CH0, 18, 2, 10, false }, { FLD_PRA, UNIT_VA, CH0, 20, 2, 10, false }, { FLD_F, UNIT_HZ, CH0, 16, 2, 100, false }, - { FLD_PF, UNIT_NONE, CH0, 24, 2, 10, false }, + { FLD_PF, UNIT_NONE, CH0, 24, 2, 1000, false }, { FLD_T, UNIT_C, CH0, 26, 2, 10, true }, { FLD_EVT_LOG, UNIT_NONE, CH0, 28, 2, 1, false }, { FLD_YD, UNIT_WH, CH0, CALC_YD_CH0, 0, CMD_CALC, false }, diff --git a/lib/Hoymiles/src/inverters/HM_2CH.h b/lib/Hoymiles/src/inverters/HM_2CH.h index e86e9c0a..9f1e4a8c 100644 --- a/lib/Hoymiles/src/inverters/HM_2CH.h +++ b/lib/Hoymiles/src/inverters/HM_2CH.h @@ -31,7 +31,7 @@ private: { FLD_PAC, UNIT_W, CH0, 30, 2, 10, false }, { FLD_PRA, UNIT_VA, CH0, 32, 2, 10, false }, { FLD_F, UNIT_HZ, CH0, 28, 2, 100, false }, - { FLD_PF, UNIT_NONE, CH0, 36, 2, 10, false }, + { FLD_PF, UNIT_NONE, CH0, 36, 2, 1000, false }, { FLD_T, UNIT_C, CH0, 38, 2, 10, true }, { FLD_EVT_LOG, UNIT_NONE, CH0, 40, 2, 1, false }, { FLD_YD, UNIT_WH, CH0, CALC_YD_CH0, 0, CMD_CALC, false }, diff --git a/lib/Hoymiles/src/inverters/HM_4CH.h b/lib/Hoymiles/src/inverters/HM_4CH.h index 4e508a9d..3d2eefe7 100644 --- a/lib/Hoymiles/src/inverters/HM_4CH.h +++ b/lib/Hoymiles/src/inverters/HM_4CH.h @@ -45,7 +45,7 @@ private: { FLD_PAC, UNIT_W, CH0, 50, 2, 10, false }, { FLD_PRA, UNIT_VA, CH0, 52, 2, 10, false }, { FLD_F, UNIT_HZ, CH0, 48, 2, 100, false }, - { FLD_PF, UNIT_NONE, CH0, 56, 2, 10, false }, + { FLD_PF, UNIT_NONE, CH0, 56, 2, 1000, false }, { FLD_T, UNIT_C, CH0, 58, 2, 10, true }, { FLD_EVT_LOG, UNIT_NONE, CH0, 60, 2, 1, false }, { FLD_YD, UNIT_WH, CH0, CALC_YD_CH0, 0, CMD_CALC, false },