fix: preserve SmartShunt energy values precision
This commit is contained in:
parent
7ebd4f4632
commit
21c19f4b7f
@ -379,8 +379,8 @@ void VictronSmartShuntStats::updateFrom(VeDirectShuntController::veShuntStruct c
|
||||
_modelName = shuntData.getPidAsString().data();
|
||||
_chargeCycles = shuntData.H4;
|
||||
_timeToGo = shuntData.TTG / 60;
|
||||
_chargedEnergy = shuntData.H18 / 100;
|
||||
_dischargedEnergy = shuntData.H17 / 100;
|
||||
_chargedEnergy = static_cast<float>(shuntData.H18) / 100;
|
||||
_dischargedEnergy = static_cast<float>(shuntData.H17) / 100;
|
||||
_manufacturer = "Victron " + _modelName;
|
||||
_temperature = shuntData.T;
|
||||
_tempPresent = shuntData.tempPresent;
|
||||
@ -401,8 +401,8 @@ void VictronSmartShuntStats::getLiveViewData(JsonVariant& root) const {
|
||||
// values go into the "Status" card of the web application
|
||||
addLiveViewValue(root, "current", _current, "A", 1);
|
||||
addLiveViewValue(root, "chargeCycles", _chargeCycles, "", 0);
|
||||
addLiveViewValue(root, "chargedEnergy", _chargedEnergy, "KWh", 1);
|
||||
addLiveViewValue(root, "dischargedEnergy", _dischargedEnergy, "KWh", 1);
|
||||
addLiveViewValue(root, "chargedEnergy", _chargedEnergy, "kWh", 2);
|
||||
addLiveViewValue(root, "dischargedEnergy", _dischargedEnergy, "kWh", 2);
|
||||
if (_tempPresent) {
|
||||
addLiveViewValue(root, "temperature", _temperature, "°C", 0);
|
||||
}
|
||||
|
||||
Loading…
Reference in New Issue
Block a user