Add target for power consumption
This commit is contained in:
parent
3f3540bd33
commit
1e968a1713
@ -148,41 +148,50 @@ void PowerLimiterClass::loop()
|
||||
}
|
||||
|
||||
int32_t newPowerLimit = 0;
|
||||
bool withinTargetRange = false;
|
||||
|
||||
if (millis() - _lastPowerMeterUpdate < (30 * 1000)) {
|
||||
newPowerLimit = static_cast<int>(_powerMeter1Power + _powerMeter2Power + _powerMeter3Power);
|
||||
// check if grid power consumption is within the upper an lower threshold of the target consumption
|
||||
if (!_consumeSolarPowerOnly &&
|
||||
newPowerLimit > (config.PowerLimiter_TargetPowerConsumption - config.PowerLimiter_TargetPowerConsumptionHysteresis) &&
|
||||
newPowerLimit < (config.PowerLimiter_TargetPowerConsumption + config.PowerLimiter_TargetPowerConsumptionHysteresis))
|
||||
withinTargetRange = true;
|
||||
else {
|
||||
if (config.PowerLimiter_IsInverterBehindPowerMeter) {
|
||||
// If the inverter the behind the power meter (part of measurement),
|
||||
// the produced power of this inverter has also to be taken into account.
|
||||
// We don't use FLD_PAC from the statistics, because that
|
||||
// data might be too old and unrelieable.
|
||||
newPowerLimit += _lastRequestedPowerLimit;
|
||||
}
|
||||
|
||||
if (config.PowerLimiter_IsInverterBehindPowerMeter) {
|
||||
// If the inverter the behind the power meter (part of measurement),
|
||||
// the produced power of this inverter has also to be taken into account.
|
||||
// We don't use FLD_PAC from the statistics, because that
|
||||
// data might be too old and unrelieable.
|
||||
newPowerLimit += _lastRequestedPowerLimit;
|
||||
newPowerLimit -= config.PowerLimiter_TargetPowerConsumption;
|
||||
|
||||
uint16_t upperPowerLimit = config.PowerLimiter_UpperPowerLimit;
|
||||
if (_consumeSolarPowerOnly && upperPowerLimit > victronChargePower) {
|
||||
// Battery voltage too low, use Victron solar power only
|
||||
upperPowerLimit = victronChargePower;
|
||||
}
|
||||
|
||||
newPowerLimit = constrain(newPowerLimit, (uint16_t)config.PowerLimiter_LowerPowerLimit, upperPowerLimit);
|
||||
|
||||
MessageOutput.printf("[PowerLimiterClass::loop] powerMeter: %d W lastRequestedPowerLimit: %d\r\n",
|
||||
static_cast<int>(_powerMeter1Power + _powerMeter2Power + _powerMeter3Power), _lastRequestedPowerLimit);
|
||||
}
|
||||
|
||||
newPowerLimit -= 10;
|
||||
|
||||
uint16_t upperPowerLimit = config.PowerLimiter_UpperPowerLimit;
|
||||
if (_consumeSolarPowerOnly && upperPowerLimit > victronChargePower) {
|
||||
// Battery voltage too low, use Victron solar power only
|
||||
upperPowerLimit = victronChargePower;
|
||||
}
|
||||
|
||||
newPowerLimit = constrain(newPowerLimit, (uint16_t)config.PowerLimiter_LowerPowerLimit, upperPowerLimit);
|
||||
|
||||
MessageOutput.printf("[PowerLimiterClass::loop] powerMeter: %d W lastRequestedPowerLimit: %d\r\n",
|
||||
static_cast<int>(_powerMeter1Power + _powerMeter2Power + _powerMeter3Power), _lastRequestedPowerLimit);
|
||||
} else {
|
||||
// If the power meter values are older than 30 seconds,
|
||||
// set the limit to config.PowerLimiter_LowerPowerLimit for safety reasons.
|
||||
newPowerLimit = config.PowerLimiter_LowerPowerLimit;
|
||||
}
|
||||
|
||||
MessageOutput.printf("[PowerLimiterClass::loop] Limit Non-Persistent: %d W\r\n", newPowerLimit);
|
||||
inverter->sendActivePowerControlRequest(Hoymiles.getRadio(), newPowerLimit, PowerLimitControlType::AbsolutNonPersistent);
|
||||
_lastRequestedPowerLimit = newPowerLimit;
|
||||
if(!withinTargetRange) {
|
||||
MessageOutput.printf("[PowerLimiterClass::loop] Limit Non-Persistent: %d W\r\n", newPowerLimit);
|
||||
inverter->sendActivePowerControlRequest(Hoymiles.getRadio(), newPowerLimit, PowerLimitControlType::AbsolutNonPersistent);
|
||||
_lastRequestedPowerLimit = newPowerLimit;
|
||||
|
||||
_lastCommandSent = millis();
|
||||
_lastCommandSent = millis();
|
||||
}
|
||||
}
|
||||
|
||||
bool PowerLimiterClass::canUseDirectSolarPower()
|
||||
|
||||
Loading…
Reference in New Issue