DPL: use vedirect isdatavalid (#283)
* DPL: use VeDirect.isDataValid() in case the communication to the Victron charger is disrupted, the respective values in VeDirect.veFrame are not invalidated such that we would notice a problem. instead, isDataValid() should be used to make sure that the Victron charger is actually alive and that we can trust to use the reported values. * DPL: simplify canUseDirectSolarPower return statement
This commit is contained in:
parent
8433820529
commit
097d464bbb
@ -216,16 +216,12 @@ bool PowerLimiterClass::canUseDirectSolarPower()
|
|||||||
CONFIG_T& config = Configuration.get();
|
CONFIG_T& config = Configuration.get();
|
||||||
|
|
||||||
if (!config.PowerLimiter_SolarPassThroughEnabled
|
if (!config.PowerLimiter_SolarPassThroughEnabled
|
||||||
|| !config.Vedirect_Enabled) {
|
|| !config.Vedirect_Enabled
|
||||||
|
|| !VeDirect.isDataValid()) {
|
||||||
return false;
|
return false;
|
||||||
}
|
}
|
||||||
|
|
||||||
if (VeDirect.veFrame.PPV < 20) {
|
return VeDirect.veFrame.PPV >= 20; // enough power?
|
||||||
// Not enough power
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
|
|
||||||
return true;
|
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
|
|||||||